BCSHF - NCFI 21-190 A, POLYMERIC MDI

Product Identification

Product ID:NCFI 21-190 A, POLYMERIC MDI
MSDS Date:11/20/1985
FSC:8010
NIIN:00N009385
MSDS Number: BCSHF

Responsible Party
NORTH CAROLINA FOAM INDUSTRIES, INC.
511 CARTER ST.
MOUNT AIRY, NC 27030

Emergency Phone: 919-789-9161

Info Phone: 919-789-9161

Cage: 3T135

Contractor
NORTH CAROLINA FOAM INDUSTRIES INC
MOUNT AIRY, NC 27030 US

Telephone: 919-789-9161

Cage: 3T135

Ingredients

TRICHLOROFLUOROMETHANE (CFC-11) (SARA III)

CAS: 75-69-4

RTECS: PB6125000

Fraction By Weight: 7%

OSHA PEL 1000 PPM

ACGIH TLV: C, 1000 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TERTIARY AMINE CATALAST

Fraction By Weight: <2%

OSHA PEL N/K

ACGIH TLV: N/K


TRICHLOROFLUOROMETHANE (CFC-11) (SARA III)

CAS: 75-69-4

RTECS: PB6125000

Fraction By Weight: 32%

OSHA PEL 1000 PPM

ACGIH TLV: C, 1000 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CFC1*3 VAPORS DISPLACE & REDUCE
BREATHING AIR IN CONFINED OR UNVENTILATED SPACES AT LEVELS ABOVE
TLV, CFC1*3 ACTS AS A WEAK NARCOTIC. OVEREXPOSURE CAUSES
TREMORS,CONFUSION,IRRITATION AND MAY RESULT IN CARDIAC
SENSITIZATION.
Explanation of Carcinogenicity:NOT LISTED AS A CARCINOGEN (NTA, IARC,
OSHA)(MFR).
Effects of Overexposure:SKIN OR EYE IRRITATION.INHAL:MDI VAPORS MAY
CAUSE BREATHLESSNESS, CHEST DISCOMFORT, COUGHING,REDUCED PULMONARY
FUNCTIONS.EXPOS MAY PRODUCE ASTHMA-LIKE SYMPTOMS, MAY LEAD TO
ALLERGIC SENSITIVITY.OVEREX P CAUSE TREMORS,CONFUSION,IRRITATION &
MAY RESULT IN CARDIAC SENSITIZATION.
Medical Cond Aggravated by Exposure:

First Aid

First Aid:EYES: FLUSH WITH FLOWING H*2O FOR AT LEAST 15 MIN OBTAIN
MEDICAL ATTENTION.SKIN:REMOVE CONTAMINATED CLOTHING & WASH OFF WITH
SOAP & H*2O.INHAL:REMOVE TO FRESH AIR,ADMINISTER OXYGEN IF
NECESSARY.INGEST : DRINK LARGE AMOUNTS OF WATER,INDUCE VOMITING.SEE
M.D.

Fire Fighting

Flash Point Method:PMCC
Flash Point:@ CFC1*3(SUPDATA
Lower Limits:
Upper Limits:
Extinguishing Media:WATER DRY CHEMICALS, CO*2.
Fire Fighting Procedures:A SELF-CONTAINED BREATHING APPARATUS SHOULD BE
WORN TO PROTECT AGAINST TOXIC & IRRITATING VAPORS. WEAR PRESSURE
DEMAND SELF-CONTAINED BREATHING APPAR(SUP DATA)
Unusual Fire/Explosion Hazard:OVERHEATED CONT MAY RUPTURE DUE TO
PRESSURE PRODUCED BY CFC1*3,CFC1*3 DECOMP TO FORM ACIDS & NOXIOUS
GASES WHEN BURNED.

Accidental Release

Spill Release Procedures:CONTAIN SPILL.ABSORB WITH SAWDUST & SHOVEL
INTO CONTAINER.WASTE MATERIAL SHOULD BE DISPOSED OF UNDER
CONDITIONS WHICH MEET FEDERAL,STATE & LOCAL ENVIRONMENTAL CONTROL
REGULATIONS.WASH AREA WITH DETERG ENT & H*2O.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:STORE BETWEEN 65&85F OUT OF
SUNLIGHT.KEEP SEALED. R COMPONENT DRUMS SEND TO RECONDITIONED OR
DISPOSE OF AS ORDINARY WASTE IAW PERTINENT REGULATIONS.
Other Precautions:UNDER NO CIRCUMSTANCE SHOULD EMPTY DRUMS BE
BURNED,CUT OPEN WITH ELECTRIC OR GAS TORCH. NO SMOKING IN AREA OF
USE.DO NOT USE IN VICINITY OF ARC WELDING,FLAMES,HOT SURFACES.MAY
CAUSE FORMATION OF CHLOR IDES,FLUORIDES OR PHOSGENE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN TLV EXCEEDED,WEAR NIOSH APPRVD ORGANIC RESP OR
AIR-SUPPLIED RESP. SPRAYING INDOORS WITHOUT ADEQ VENT AIR-SUPPLIED
RESP MUST BE WORN.
Ventilation:PROVIDE LOCAL EXHAUST TO STAY BELOW TLV.
Protective Gloves:CHEMICALLY RESISTANT RUBBER OR PLASTIC.
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:EYE WASH SYSTEM & SAFETY SHOWERS SHOULD BE
AVAILABLE.
Work Hygienic Practices:OBSERVE GOOD WORK HYGIENIC PRACTICES.
Supplemental Safety and Health
BP: 23.89C. FL PT: EVAP 390F 198.89C. SPECIAL FIRE FIGHTING
PROCEDURES:& FULL PROTECTIVE EQUIPMENT. UNUSUAL FIRE & EXPLO:
OVERHEATED CONTR RUPTURE DUE TO CFC1*3 PRESSURE: THERMAL DECOMP
PRODUCTS MAY I NCLUDE FLUORIDES,CHLORIDES,PHOSGENEHAZ DECOMP:
FLUORIDES & PHOSGENE .

Chemical Properties

Boiling Pt:B.P. Text:6FC1*3 75F
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:
Vapor Density:N/K
Spec Gravity:1.31
pH:
Evaporation Rate & Reference:N/K
Solubility in Water:INSOLUBLE, REACTS
Appearance and Odor:BROWN LIQUID, SLIGHTLY AROMATIC.
Percent Volatiles by Volume:28
Corrosion Rate:

Stability

Stability Indicator/Materials to Avoid:YES
N/K
Stability Condition to Avoid:TEMPERATURES OVER 85F.
Hazardous Decomposition Products:WHEN BURNED; CO*2,CO,NO*XALIPHATIC
FRAGMENTS HF,HCL.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.